 | Magendans Dynamic Filtration System DFS-03 |
|
|
|
|
This instrument has been developed to quickly and accurately determine the influence of chemicals on filtration properties by automatic analysis of drainage and retention of fiber suspensions.
|
|
|
The instrument can be operated very simply from the computer program. This program allows all of the relevant data to be entered. A mixing profile can also be programmed, that can be used to simulate process conditions.
|
|
|
After setting the necessary parameters, you are requested to feed the material to be measured into the instrument, following the mixing profile will run its program. When this is completed, the valve will automatically open and filtration will take place. The amount of filtrate is continuously measured with approximately 5 samples per second. This is displayed in a graph showing the amount of filtrate as a function of time. The computer program can be used to compare all of the graphs by displaying them in the window. It is possible to add all sorts of parameters to the graph, so that comparable graphs are created, such as the dosed amount of chemicals compared to the dehydration velocity.
|
|
|
|
|
A second function of the instrument is to make a filtrate in order to determine the retention. Different mixing gear is provided for simulating practical conditions as well as a magnetic valve under the filter. The mixing gear ensures that the filter remains clean. The retention is calculated by determining the amount of dry matter in the filtrate and in the original material and entering these data into the computer program. It is also possible here to make various graphs with the program, and to compare all of the parameters.
|
technical data:
|
|
Power Supply:
|
90-240 VAC, 50-60 Hz
|
|
Weight:
|
22 kg incl. flightcase and accessories
|
|
Dimensions device:
|
180 x 502 x 240 mm (WxHxD)
|
|
|
|
|
Sample requirements
|
|
|
Sample Volume:
|
500-1000 ml
|
|
Sample consistency:
|
0,5-2,0 %
|
|
|
|
|
System requirements
|
|
|
Operating system:
|
Windows 98, NT, XP
|
|
Interface:
|
RS232, 9-Pin
|
|
|
|
|
Analytical findings:
|
|
|
Drainage chart (time vs. mass of filtrate)
|
|
|
Total retention
|
|
|
Filler retention
|
|
|
|
included accessories:
|
balance, 5 screens of different wire sizes, Stirrer for retention measurement, Stirrer for drainage measurement, Outlet valve for retention measurement, Filtrate outlet for drainage measurement, PC Software
|
features:
|
 |
A mixing chamber with a cone valve and screen at its bottom.
|
 |
The filtrate is caught in a beaker that stands on scales.
|
 |
The instrument is computer controlled.
|
|
|
|
Here you can download the product folder: dfs03eng.pdf [3.123 KB]
|
|
Support DFS 03
|